Related issues
Jira Legacy | ||||||
---|---|---|---|---|---|---|
|
Transformation / Translation Errors
In the Tiani solution the errors for CDA documents was handled in an object. The advantage with using Objects for this is that you can handle more then one exception which is the case for a CDA documents that can have many errors or partial errors. As its done now At the moment in the openNCP only one error is handled since its throwing an exception directly in the code. Another thing that was also contained in the object that tiani had was the actual exception offcourse(epsos-client-connector) these errors is not handled at all what I have seen. I can se the messages in the NCP-B log, but they aint sent over to the portal. Dont know if it is handled at all in the other parts in the openNCP.
Here is an example of how this is handled in the epSOS-Web.
Code Block |
---|
if (!rsp.getPartialErros().isEmpty()) { for (int i = 0; i < rsp.getPartialErros().size(); i++) { ErrorFeedback error = new ErrorFeedback(); error.setErrorCode(rsp.getPartialErros().get(i).getErrorCode()); error.setErrorMessage(rsp.getPartialErros().get(i).getCodeContext()); error.setSeverityType(rsp.getPartialErros().get(i).getSeverity()); errorList.add(error); } } |
...
My suggestion is that we do it in the Tiani way. And uses an object to handle the errors in the response to the portal.
Example of a XCA error message:
Code Block |
---|
<RegistryResponse
status="urn:ihe:iti:2007:ResponseStatusType:PartialSuccess" xmlns="urn:oasis:names:tc:ebxml-regrep:xsd:rs:3.0">
<RegistryErrorList>
<a:RegistryError codeContext="Not valid CDA document"
errorCode="4504"
severity="urn:oasis:names:tc:ebxml-regrep:ErrorSeverityType:Error" xmlns:a="urn:oasis:names:tc:ebxml-regrep:xsd:rs:3.0">ECDATransformationHandler.Error.toEpSOSPivot(4504 / Not valid CDA document)</a:RegistryError>
<a:RegistryError
codeContext="Code System not found [CodedElement [code=459099, codeSystemName=Nordisk Produktkod, oid(codeSystem)=1.2.752.129.2.1.5.1]]"
errorCode="4501"
severity="urn:oasis:names:tc:ebxml-regrep:ErrorSeverityType:Error" xmlns:a="urn:oasis:names:tc:ebxml-regrep:xsd:rs:3.0">ECDATransformationHandler.Error.toEpSOSPivot(4501 / Code System not found [CodedElement [code=459099, codeSystemName=Nordisk Produktkod, oid(codeSystem)=1.2.752.129.2.1.5.1]])</a:RegistryError>
<a:RegistryError
codeContext="Code System not found [CodedElement [code=SUBST, codeSystemName=ActClass, oid(codeSystem)=2.16.840.1.113883.5.6]]"
errorCode="4501"
severity="urn:oasis:names:tc:ebxml-regrep:ErrorSeverityType:Error" xmlns:a="urn:oasis:names:tc:ebxml-regrep:xsd:rs:3.0">ECDATransformationHandler.Error.toEpSOSPivot(4501 / Code System not found [CodedElement [code=SUBST, codeSystemName=ActClass, oid(codeSystem)=2.16.840.1.113883.5.6]])</a:RegistryError>
<a:RegistryError
codeContext="CodeSystem name doesn't match provided name [SubstanceAdminSubstitution != substanceAdminSubstitution]"
errorCode="2508"
severity="urn:oasis:names:tc:ebxml-regrep:ErrorSeverityType:Warning" xmlns:a="urn:oasis:names:tc:ebxml-regrep:xsd:rs:3.0">ECDATransformationHandler.Error.toEpSOSPivot(2508 / CodeSystem name doesn't match provided name [SubstanceAdminSubstitution != substanceAdminSubstitution])</a:RegistryError>
</RegistryErrorList>
</RegistryResponse>
|
If we do it like this there will be changes in the wsdl (client-connectors return messages). Since there is no way to handle it with the current api.
Error messages handling