Test Id | PT_CLIENT_XCA_EP_#5.2 | ||||||
---|---|---|---|---|---|---|---|
Name | testQueryEPConsiderAddDoc | ||||||
Description | The HCP MUST consider additionally the source coded document because it MAY contain information that is not included in the epSOS pivot CDA . Reason: field were | ||||||
Test Inputs | A request for a document which will cause a Source coded document must be considered success. | ||||||
Expects | Response Status: Success Message: Source coded document must be considered Code: 2102 | ||||||
Status |
|
...
Retrieve Tests
...
MRO Service
Normal Usage
This tests represent the normal usage of Patient MRO Service.
Test
...
#0 : "
...
testQueryMro"
...
Test Id | PT_CLIENT_XCA_ PSMRO_ #9#0 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Name | testRetrievePS testQueryMro | |||||||||
Description | This test performs an XCA Retrieve Query for PSMRO, using valid Document Patient Identifiers. It is a simple test designed uniquely for testing the normal work-flow of the XCA Retrievequery. | |||||||||
Test Inputs | Valid document patient identifier.
| |||||||||
Expects | A list, containing valid document identifiers. | |||||||||
Status |
|
Invalid Scenarios
Test #9.1 : "testRetrievePSCIM"
Test Id | PT_CLIENT_XCA_PS_#9.1 | ||||||
---|---|---|---|---|---|---|---|
Name | testRetrievePSCIM | ||||||
Description | Error messages related to the creation of the document content. There may be cases where failure may result in some elements of clinical information missing for example in a patient summary. These clinical content errors should be conveyed within the document content. | ||||||
Test Inputs | Some elements of clinical information missing. | ||||||
Expects | A list, containing valid document identifiers. | ||||||
Status |
|
Order Service
Normal Usage
This tests represent the normal usage of Order Service.
...
...
Anchor | ||||
---|---|---|---|---|
|
Retrieve Tests
Patient Service
Normal Usage
This tests represent the normal usage of Patient Service.
Test #9 : "testRetrievePS"
Test Id | PT_CLIENT_XCA_PS_#9 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Name | testRetrievePS | |||||||||
Description | This test performs an XCA Retrieve for PS, using valid Document Identifiers. It is a simple test designed uniquely for testing the normal work-flow of the XCA Retrieve. | |||||||||
Test Inputs | Valid document identifier.
| |||||||||
Expects | A valid document. | |||||||||
Status |
|
Invalid Scenarios
Test #9.1 : "testRetrievePSCIM"
Test Id | PT_CLIENT_XCA_EPPS_#9.1 | ||||||
---|---|---|---|---|---|---|---|
Name | testRetrieveEPtestRetrievePSCIM | ||||||
Description | This test performs an XCA Retrieve for EP, using valid Document Identifiers. It is a simple test designed uniquely for testing the normal work-flow of the XCA Retrieve. | Test Inputs | Valid document identifier. Code Block | | |||
| |||||||
Test Inputs | Some elements of clinical information missing. | ||||||
Expects | A list, containing valid document identifiers. | ||||||
Status |
|
Order Service
Normal Usage
This tests represent the normal usage of Order Service.
Test #9 : "testRetrieveEP"
Test Id | PT_CLIENT_XCA_EP_#9 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Name | testRetrieveEP | |||||||||
Description | This test performs an XCA Retrieve for EP, using valid Document Identifiers. It is a simple test designed uniquely for testing the normal work-flow of the XCA Retrieve. | |||||||||
Test Inputs | Valid document identifier.
| |||||||||
Expects | A valid document. | |||||||||
Status |
|
Invalid Scenarios
The invalid scenarios for Patient Service testing are described in WP3.4 Deliverable D3.4.2 - Common Components Specification v2.2 (Pages: 58 and 59).
N/A
MRO Service
Normal Usage
This tests represent the normal usage of MRO Service.
Test #1 : "testRetrieveMro"
Test Id | PT_CLIENT_XCA_MRO_#0 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Name | testRetrieveMro | |||||||||
Description | This test performs an XCA Retrieve for MRO, using valid Document Identifiers. It is a simple test designed uniquely for testing the normal work-flow of the XCA Retrieve. | |||||||||
Test Inputs | Valid document identifier.
| |||||||||
Expects | A valid document. | |||||||||
Status |
|
Invalid Scenarios
The invalid scenarios for Patient Service testing are described in WP3.4 Deliverable D3.4.2 - Common Components Specification v2.2 (Pages: 58 and 59).
...
References
WP3.4 Deliverable D3.4.2 - Common Components Specification v2.2 (Pages: 33, 44 and 59)
IHE International: IHE IT Infrastructure (ITI) Technical Framework. Volume 1: Integration Profiles. August 2011.
...