Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Content of the Protocol Terminators
Page Tree | ||||||
---|---|---|---|---|---|---|
|
XCPD Service Integration Testing
This page tries to gather all the specification of Integration testing for the XCPD client component, including several aspects such as the description, inputs, results and last passed date.
Note |
---|
Work in progress! |
Note | ||
---|---|---|
| ||
These test definitions match the code implementation. The same Id and Test Name is used in method definitions. Please follow the same convention and remember to reflect the code changes in these tables and vice-versa. |
Initial Information
If the epSOS Identification Service provider does not find a matching patient identifier it SHOULD include a <reasonOf/> element with the response message:
Code Block | ||||
---|---|---|---|---|
| ||||
<reasonOf typeCode="RSON"> <detectedIssueEvent classCode="ALRT" moodCode="EVN"> <code code="ActAdministrativeDetectedIssueCode" codeSystem="2.16.840.1.113883.5.4"/> <!— details on detected issue and proposed activity --> </detectedIssueEvent> </reasonOf> |
Test Harness
Test #1 : "testQueryIdOnly"
Test Id | PT_SERVER_XCPD_#1 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryIdOnly | |||||||
Description | The service requestor tried an identification based on an ID only or did not provide enough data to univocally identify the patient. (WARNING) The HCP SHOULD ask the patient for further demographics and re-issue the request. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). OK (data found, no errors) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | Identification based on an ID only or not enough data to univocally identify the patient | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #2 : "testQueryDemographicsOnly"
Test Id | PT_SERVER_XCPD_#2 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryDemographicsOnly | |||||||
Description | The service provider only allows for patient identification by national/shared ID (WARNING) The HCP SHOULD ask the patient for a national (health care) identification card and reissue the request using Shared/national Patient Identifier Query and Feed mode. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | Query only using Patient Demographics | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #3 : "testQueryEHICardOnly"
Test Id | PT_SERVER_XCPD_#3 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryEHICardOnly | |||||||
Description | The service provider only allows for patient identification by national health card or EHIC. Queries based on demographics only are not supported (WARNING) The HCP SHOULD ask the patient for a health care identification card and re-issue the request. AA (application accept) is returned in Acknowledgement.typeCode (transmissionwrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | Query without using EHIC Card. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #4 : "testQueryPrivateData"
Test Id | PT_SERVER_XCPD_#4 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryPrivateData | |||||||
Description | The service provider does not accept the query because responding MAY lead to a disclosure of private patient data (ERROR). The HCP SHOULD limit the provided traits and re-issue the request. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | Private data that may lead to a disclosure. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #5 : "testQueryInsRights"
Test Id | PT_SERVER_XCPD_#5 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryInsRights | |||||||
Description | The requestor has insufficient rights to query for patient’s identity data (ERROR). If access to the patient’s medical data is required at the PoC this MUST be performed by a person with additional permissions. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | A request with a requestor with insufficient rights. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #6 : "testQueryPatientAuthId"
Test Id | PT_SERVER_XCPD_#6 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryPatientAuthId | |||||||
Description | Patient authentication MUST be piggybacked with patient identification. A respective identifier (e.g. GSS TAN) was not provided (ERROR) The HCP at the PoC SHOULD ask the patient for a respective identifier and SHOULD re-issue the request. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | Patient authentication not piggybacked with patient identification. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #7 : "
testQueryPatientAuthIdtestQueryMinAccur"
Test Id | PT_SERVER_XCPD_#7 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryPatientAuthIdtestQueryMinAccur | |||||||
Description | The service provider did not find a match with the given minimum accuracy. (INFO) The service consumer SHOULD re-issue the AA (application accept) is returned in Ac- OK (data found) is returned in QueryAck- | |||||||
Test Inputs | Patient authentication not piggybacked with patient identificationA request with high level of confidence. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #8 : "testQueryInvalidTraits"
Test Id | PT_SERVER_XCPD_#8 | |||||||
---|---|---|---|---|---|---|---|---|
Name | testQueryInvalidTraits | |||||||
Description | The identity traits provided by the service consumer are not supported by the service provider. (ERROR) The service consumer SHOULD re-issue the request with a different set of identity traits. AA (application accept) is returned in Acknowledgement.typeCode (transmission wrapper). AE (application error) is returned in QueryAck.queryResponseCode (control act wrapper) | |||||||
Test Inputs | A request with unsupported identity traits. | |||||||
Expected Results |
| |||||||
Last Passed Date |
|
Test #X : "testXXXX"
Test Id | PT_SERVER_XCPD_#X | ||||||
---|---|---|---|---|---|---|---|
Name | testXXXX | ||||||
Description | Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Aliquam fermentum vestibulum est. Cras rhoncus. Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. | ||||||
Test Inputs | Lorem ipsum dolor sit amet, consectetuer adipiscing elit. Aliquam fermentum vestibulum est. Cras rhoncus. Pellentesque habitant morbi tristique senectus et netus et malesuada fames ac turpis egestas. | ||||||
Expected Results | N/A | ||||||
Last Passed Date |
|